Arată înregistrarea sumară a articolului

dc.contributor.authorCîrnu, Carmen-Liliana
dc.contributor.authorȘerban, Anca
dc.date.accessioned2017-10-12T10:29:19Z
dc.date.available2017-10-12T10:29:19Z
dc.date.issued2013-10-01
dc.identifier.urihttp://10.11.10.50/xmlui/handle/123456789/4425
dc.description.abstractThe design parameters such as nozzle slot, generator’s slot, resonance chamber diameter, resonator neck length, inlet port diameter are required to determine the optimal operating parameters while using the sonic generator for water treatment. These parameters determine the optimal values of functional parameters that induce best results within the water treatment process. The design calculation achieves the necessary values of the operating parameters which are the supply air pressure, air mass flow, generators frequency.ro_RO
dc.language.isoenro_RO
dc.publisherUniversitatea "Dunărea de Jos" din Galațiro_RO
dc.subjectgenerator sonicro_RO
dc.subjectunde sonorero_RO
dc.subjectrezonatorro_RO
dc.subjectparametri de proiectarero_RO
dc.subjectsonic generatorro_RO
dc.subjectsound wavesro_RO
dc.subjectresoantorro_RO
dc.subjectdesign parametersro_RO
dc.titleThe Calculation Procedure of Experimental Sonic Generator with Two Resonators Designed for Water Treatment Processesro_RO
dc.title.alternativeProcedura de calcul a generatorului sonic experimental cu două rezonatoare concepute pentru procesele de tratare a apeiro_RO
dc.typeArticlero_RO


Fișiere la acest articol

Thumbnail

Acest articol apare în următoarele colecții(s)

Arată înregistrarea sumară a articolului