dc.description.abstract | The design parameters such as nozzle slot, generator’s slot, resonance
chamber diameter, resonator neck length, inlet port diameter are required
to determine the optimal operating parameters while using the sonic
generator for water treatment. These parameters determine the optimal
values of functional parameters that induce best results within the water
treatment process. The design calculation achieves the necessary values of
the operating parameters which are the supply air pressure, air mass flow,
generators frequency. | ro_RO |